การอ่าน LED Error on BrightSign

Green power (Pwr): Displays when the board is powered up and not in reset mode. Flashes during firmware update process.

Green file-system activity (Bsy): Flashes any time there is file-system activity (on any storage device).

Blue WiFi: Flashes when the player is connecting to the wireless network. Displays when connected.

Red status (Err): Flashes a certain number of times to indicate which error is occurring. The flash codes are described below.

  • 2 Unspecified error

  • 3 Network recovery script is preparing to run on a device configured for network recovery (BrightSign Network)

  • 3 No published content or script on the SD card

  • 4 No upgrade file found. This is often the result of the player being in Rescue Mode; to complete Rescue Mode, insert an SD card with a .bsfw firmware update file in the root folder (the error code will continue to display for a few seconds while the update file is checked for integrity).

  • 5 Failed to load kernel module

  • 5 OS initialization failed (Init shell script failed)

  • 6 Board is not capable of running the current firmware version

  • 7 A piece of on-board hardware is not working correctly

  • 8 Problem related to the storage device (either a USB drive or SD card)

  • 9 Problem related to the registry/NAND

  • 10 The autorun script encountered a load/run error (commonly caused by a locked or NTFS-formatted SD card)

  • 11 WiFi-related error (mainly, WiFi not found on USB)

  • 12 Unable to find bootable image

  • 13 The root file system has failed verification, which is used to detect whether the file system has been tampered with. You can recover a player that is showing this error code by performing a firmware update with secure boot (ตามไฟล์แนบ).

  • 14 Boot loader failure