การอ่าน LED Error on BrightSign
Green power (Pwr): Displays when the board is powered up and not in reset mode. Flashes during firmware update process.
Green file-system activity (Bsy): Flashes any time there is file-system activity (on any storage device).
Blue WiFi: Flashes when the player is connecting to the wireless network. Displays when connected.
Red status (Err): Flashes a certain number of times to indicate which error is occurring. The flash codes are described below.
2 Unspecified error
3 Network recovery script is preparing to run on a device configured for network recovery (BrightSign Network)
3 No published content or script on the SD card
4 No upgrade file found. This is often the result of the player being in Rescue Mode; to complete Rescue Mode, insert an SD card with a .bsfw firmware update file in the root folder (the error code will continue to display for a few seconds while the update file is checked for integrity).
5 Failed to load kernel module
5 OS initialization failed (Init shell script failed)
6 Board is not capable of running the current firmware version
7 A piece of on-board hardware is not working correctly
8 Problem related to the storage device (either a USB drive or SD card)
9 Problem related to the registry/NAND
10 The autorun script encountered a load/run error (commonly caused by a locked or NTFS-formatted SD card)
11 WiFi-related error (mainly, WiFi not found on USB)
12 Unable to find bootable image
13 The root file system has failed verification, which is used to detect whether the file system has been tampered with. You can recover a player that is showing this error code by performing a firmware update with secure boot (ตามไฟล์แนบ).
14 Boot loader failure